IDENTIFINDER R500
HIGHLY SENSITIVE HANDHELD SPECTROSCOPIC DETECTION & IDENTIFICATION
The fastest and most sensitive radionuclide identification device (RID) for detection and identification of radiation sources. The identiFINDER R500 is as easy to use as it is powerful. This product is the ideal solution for truck and cargo checks, for large area scanning and for locating, and identifying shielded sources.
CUSTOM APPLICATIONS
• Truck and cargo checks
• Large area scanning
• Locate and identify shielded sources
• Critical infrastructure security
FEATURES & BENEFITS
• Detects radiation source within a few seconds
• Gamma and neutron detection
• Identifies ANSI N42.34 library
• Rugged (1.0-m drop tested)
• High resolution and low false alarms
• Rapid visible, audible, and tactile alerts
• Fast, two-minute start up
• 5 year factory maintenance
SPECIFICATIONS
TECHNOLOGY |
||
Technology |
Radioisotope identification device (RIID) |
|
Product Variants |
ULCS-NG1, ULCS-NGH2, UL-LGH3, UL-LG4 |
|
Gamma (Nal) 1,2 |
102 x 19 mm |
|
Gamma (LaBr3) 3, 4 |
38 x 38 mm |
|
Neutrons (He-3) 2,3 |
19 x 106 mm |
|
Gamma (High Dose Rate) |
Geiger-Müller |
|
Energy Range (Gamma) |
20 keV – 3 MeV |
|
Corrections |
Real-time linearization of gamma spectrum |
|
Gamma Spectrum |
1024 channels; 3 MeV |
|
Dose Rate / Accuracy (Cs-137) |
0.000 nSv/h – 1.00 mSv/h (0 nrem/h – 100 mrem/h) / ±30 % |
|
Scintillator Dose Rate Range |
0 nSv/h - 50 μSv/h (0 nrem/h - 5.0 mrem/h) |
|
Geiger-Müller Dose Rate Range |
10 μSv/h - 1.0 mSv/h (1.0 mrem/h - 100 mrem/h) |
|
Dose Range |
0 μSv - 1 Sv (0 μrem - 100 rem) |
|
Overload Dose Rate Range |
1 mSv/h - 10 mSv/h (100 mrem/h - 1.0 rem/h) |
|
Neutron Sensitivity |
Variants 2, 3: 9 cps/nv; ±15 % |
|
Stabilization |
Calibration source; LED |
|
Typical Resolution |
Variants 1, 2: ≤8 % FWHM; Variants 3, 4: 3.5% FWHM at 662 keV |
|
Service Interval |
Variants 1, 2: ≤8 % FWHM; Variants 3, 4: 3.5% FWHM at 662 keV |
|
SAMPLING & ANALYSIS |
||
Sample Introduction |
Absorption of EM gamma or neutron emissions |
|
Threats |
Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material |
|
Nuclide Identification |
According to ANSI N42.34 |
|
Sampling & Analysis |
From a few seconds to minutes |
|
SYSTEM INTERFACE |
||
Display & Alerts |
Transflective color LCD |
|
Communication |
USB 2.0; mini-B socket; Bluetooth® Class 2.0, ≤10m range (removable) |
|
Data Storage |
2GB internal memory; up to 600,000 spectra |
|
Training Requirements |
||
GPS (removable) |
12-channel SiRF III receiver |
|
Software |
On-board webserver software |
|
POWER |
||
Input Voltage |
100-240 VAC (wall adapter, car adapter and USB cable supplied) |
|
Battery Specs |
FLIR powerPACK ultra 2 (LSD NiMH, rechargeable); ≥8h operational battery life; recharge ≤4h when using AC; recharge >4h when using USB |
|
Cold Start Time |
||
ENVIRONMENTAL |
||
Operating Temp |
-20 to 50 °C |
|
Operating Humidity |
10 % – 80 % |
|
Storage Temp |
-10 to 35 °C |
|
PHYSICAL FEATURES |
||
Dimensions (L x W x H) |
21.1 x 12.9 x 32.3 cm - with battery |
|
Weight |
≤2.9 kg |
|
Enclosure & Protection |
Aluminum housing; protection rating IP54 according to IEC 60529 |