FIDO B2
Bio-Threat Detection & Collection
The FLIR Fido B2 is a continuous, real-time air monitor that detects bio-agents in less than 60 seconds. Fido B2 uses IBAC technology to reliably detect all four classes of bio-threats with low false alarm rates and no consumables. As the most mature and widely deployed biological trigger on the market today, the Fido B2 offers a proven, field-ready solution for bio-aerosol monitoring.
CUSTOM APPLICATIONS
· Building protection
· Special event monitoring
· Mission-based incident response
· Force protection
· Mass transit security
FEATURES & BENEFITS
· Affordable, real-time warning capability for bio-aerosol threats
· Detects spores, bacteria, virus, and toxins
· Autonomous 24/7 operation with no consumables
· Alarm automatically triggers sample collection
· Detection algorithms for indoor and outdoor use
· Compact, lightweight, and rugged
· Integrates with facility monitoring and control systems
SPECIFICATIONS
TECHNOLOGY |
|||
Technology |
UV Laser Induced Fluorescence (LIF) |
||
SAMPLING & ANALYSIS |
|
||
Sample Introduction |
Airborne particles; triggered aerosol sample collector |
||
Sample Phase |
Aerosol; flow rate 4.0 L/min (0.14 ft3/min) |
||
Threats |
Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns |
||
Sensitivity |
|||
Sampling & Analysis |
Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time configurable down to 1 second |
||
Sample Collection |
Integrated with DFU or C100 sample collector (see below) |
||
SYSTEM INTERFACE |
|||
Display & Alerts |
On-board LED for visual indication; full display via software on external computer |
||
Communication |
Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz) |
||
Outputs |
Particle data, sensor diagnostics, bio-alarm, and fault |
||
Data Storage |
Internal 2 GB MicroSD memory card; stores over 1 yr of data |
||
Training Requirements |
|||
POWER |
|||
Input Voltage |
100-240 VAC (adapter supplied); 18-36 VDC |
||
Power Consumption |
20 W (normal detector operation) 75 W (with collector running) |
||
Battery Specs |
Li-ion BB 2590 military battery; up to 14 hrs runtime; charge |
||
Cold Start Time |
|||
ENVIRONMENTAL |
|||
Operating Temp |
-20 to 50 °C |
||
Operating Humidity |
5% to 95%, non-condensing |
||
Storage Temp |
-40 to 70 °C |
||
PHYSICAL FEATURES |
|||
Dimensions (L x W x H) |
24.0 x 16.5 x 22.9 cm - without battery |
||
Weight |
3.4 kg |
||
Enclosure & Protection |
Aluminum, IP66 weatherproof |
||
INTEGRATED SAMPLE COLLECTOR SPECIFICATIONS |
|||
|
DFU Collector |
C100 Collector |
|
Sampling Method |
Dry collection |
Wet or dry collection |
|
Power Consumption |
60 watts |
60 watts |
|
Dimensions (H x Diameter) |
8.9 x 7.6 cm |
11.4 x 14 cm |
|
Weight |
0.6 kg |
1.4 kg |
|
Max Flow Rate |
100 L/min |
200 L/min |
|
Particle Size |
1 to 10 microns |
1 to 10 microns |
|
Collection Media |
Dry sampling – polyester felt filters |
Wet sampling - buffer rinse fluid |
|
Sample Recovery |
Particle extraction from filter performed in vial with liquid buffer |
Manual liquid rinse performed |