FIDO B2 Bio-Threat Detection & Collection The FLIR Fido B2 is a continuous, real-time air monitor that dete.. Product #: based on 0 Reviews Regular price: $0.00 $0.00

FIDO B2

Bio-Threat Detection & Collection

The FLIR Fido B2 is a continuous, real-time air monitor that detects bio-agents in less than 60 seconds. Fido B2 uses IBAC technology to reliably detect all four classes of bio-threats with low false alarm rates and no consumables. As the most mature and widely deployed biological trigger on the market today, the Fido B2 offers a proven, field-ready solution for bio-aerosol monitoring.

CUSTOM APPLICATIONS

·        Building protection

·        Special event monitoring

·        Mission-based incident response

·        Force protection

·        Mass transit security 

FEATURES & BENEFITS

·        Affordable, real-time warning capability for bio-aerosol threats

·        Detects spores, bacteria, virus, and toxins 

·        Autonomous 24/7 operation with no consumables

·        Alarm automatically triggers sample collection

·        Detection algorithms for indoor and outdoor use

·        Compact, lightweight, and rugged 

·        Integrates with facility monitoring and control systems

SPECIFICATIONS

TECHNOLOGY

 

Technology

UV Laser Induced Fluorescence (LIF)

 

SAMPLING & ANALYSIS

 

 

Sample Introduction

 Airborne particles; triggered aerosol sample collector

 

Sample Phase

Aerosol; flow rate 4.0 L/min (0.14 ft3/min)

 

Threats

Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns

 
 

Sensitivity 

   

Sampling & Analysis

Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time configurable down to 1 second

 

Sample Collection

Integrated with DFU or C100 sample collector (see below)

 

SYSTEM INTERFACE

 

Display & Alerts

 On-board LED for visual indication; full display via software on external computer

 

Communication

Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz)

 

Outputs

Particle data, sensor diagnostics, bio-alarm, and fault

 

Data Storage

Internal 2 GB MicroSD memory card; stores over 1 yr of data

 

Training Requirements

   

POWER

 

Input Voltage

100-240 VAC (adapter supplied); 18-36 VDC

 

Power Consumption

20 W (normal detector operation) 75 W (with collector running)

 

Battery Specs

Li-ion BB 2590 military battery; up to 14 hrs runtime; charge

 

Cold Start Time

   

ENVIRONMENTAL

 

Operating Temp

-20 to 50 °C

 

Operating Humidity

5% to 95%, non-condensing

 

Storage Temp

-40 to 70 °C

 

PHYSICAL FEATURES

 

Dimensions (L x W x H)

24.0 x 16.5 x 22.9 cm - without battery

 

Weight

3.4 kg

 

Enclosure & Protection 

Aluminum, IP66 weatherproof

 

INTEGRATED SAMPLE COLLECTOR SPECIFICATIONS

 

 

DFU Collector

C100 Collector

 

Sampling Method

Dry collection

Wet or dry collection

 

Power Consumption

60 watts

60 watts

 

Dimensions  (H x Diameter)

8.9 x 7.6 cm

11.4 x 14 cm

 

Weight

0.6 kg

1.4 kg

 

Max Flow Rate

100 L/min

200 L/min

 

Particle Size

1 to 10 microns

1 to 10 microns

 

Collection Media

Dry sampling – polyester felt filters
(47mm diameter, 1 micron)

Wet sampling - buffer rinse fluid
provided in premeasured vials

 

Sample Recovery

Particle extraction from filter performed in vial with liquid buffer

Manual liquid rinse performed
at collector, yields 6mL of liquid