AllClear
AllClear is a handheld, battery-powered, passive millimeter wave people screening device that detects metallic and non-metallic objects. The screening device is an alternative to intrusive pat-downs by providing a high-level of object detection.
AllClear is a passive millimeter wave system, only measuring the natural energy emitted by the body and does not emit harmful radiation. Millimeter waves are naturally occurring forms of electromagnetic wave energy. Visual body images are not captured, ensuring privacy.
When an object is detected AllClear alerts the user through lights (LEDs), as well as sound or vibration, depending on the mode selected. AllClear only requires one operator, minimal training, and is easy to use. With AllClear, security personnel can easily detect concealed items while protecting the safety and privacy of people being scanned.
APPLICATIONS
• Physical security checkpoints
• Flexible deployment options
• Indoor use only
SENSITIVITY
• Metals (ferrous and non-ferrous)
• Non-metals
- Plastics, liquids, gels
- Ceramics, powders, explosives
- Currency, drugs
- Media and electronics
EASE-OF-USE
• Ready-to-use
• Web-based training
• User guide booklet
• Simplified controls and indicators
• Automatic threat detection
COST-EFFECTIVE
• No regular maintenance needed
• 100% portable, battery operated
• Extended use and durability
Specifications
• Power Supply: 100–240 VAC external charger supplies 12V DC, 20W max. Charger has the following interchangeable plugs: United States, European, United Kingdom, and Australia/New Zealand
• Operating Temperature: 32°F to 115°F (0°C to 46°C)
• Storage Temperature: 19°F to 120°F (-7ºC to +49ºC)
• Operating Environment: For indoor use only
• Dimensions: 18.38 x 3.54 x 2.83 in (467 x 90 x 72 mm)
• Weight: 23.6 oz. (680 g)
• Numbers of Sensors: 7 radiometric MMW sensors
• Battery: Lithium ion 3.7 volt internal battery pack, 5800 mAh
• Battery Life: Up to 16 hours
Controls
• Power Button: Powers AllClear on and off. Illuminates green/yellow/red to indicate charging and battery status.
• Mode Button: Cycles through alert modes and volume levels for audible alert.
• Zero: Zeros the AllClear. Flashes yellow to indicate when unit is ready to be zeroed (to equalize the sensors).
• Alert Indicator LEDs (2): Illuminates red when the MMW sensors detect an object.
• Sensor Indicator LEDs (7): Synched with 7 MMW sensors to indicate the locality of the detected object.
Each LED illuminates blue when the related sensor detects an object.